Permit: T04CM02477

Parcel: 12106220A


Addresses:

5597 E LEE ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/16/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/ 1) CORRECTIONS MADE OK 2) OK TO COVER
07/08/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/ 1) NO PROTECTING VENT INSTALLED DOWNSTREAM OF TRAP. NO TEST ON NEW PIPING. TRENCH FULL OF WATER 2) PLEASE NOTE: IF YOU WISH TO USE A FUNNEL DRAIN FOR AN INDIRECT WASTE RECEPTER FOR CONDENSATE IT WILL NEED TO HAVE A TRAP PRIMER INSTALLED (NOT NOTED ON PLAN) 3) PROVIDE REVISED PLAN, SHOWING VENT FOR FUNNEL DRAIN AND TRAP PRIMER INSTALLATION, BY NEXT INSPECTION