| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2004 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 08/09/2004 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ALL SHEAR WALLS SHALL LAP 3/4" MINIMUM TO BOTTOM PLATE WITH NAILS 3/8" MINIMUM FROM EDGE |
|
| 08/09/2004 | SHEET ROCK NAILING | Denied | 1) GARAGE #2 SHEAR WALL DOES NOT OVERLAP BOTTOM PLATE A MINIMUM OF 7/8" (3/8" FROMEDGE OF DRYWALL AND PLATE) 2) GARAGE TOP PLATES NAILED AT 8" ON CENTER MAXIMUM ALLOWED 7" ON CENTER 3) BEDROOM 2 #2 SHEARWALL BLOCKS NOT NAILED 4) M/BR TOP AND BOTTOM PLATES NOT NAILED AT 7" ON CENTER ON #2 SHEARWALL ALSO DEN 5) BEDROOM 3 #3 SHEAR MID BLOCKS NOT NAILED |