Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM02474

Parcel: 140107330

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
08/10/2004 SHEET ROCK NAILING Approved IVRS - Inspection :*
08/09/2004 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ALL SHEAR WALLS SHALL LAP 3/4" MINIMUM TO BOTTOM PLATE WITH NAILS 3/8" MINIMUM FROM EDGE
08/09/2004 SHEET ROCK NAILING Denied 1) GARAGE #2 SHEAR WALL DOES NOT OVERLAP BOTTOM PLATE A MINIMUM OF 7/8" (3/8" FROMEDGE OF DRYWALL AND PLATE) 2) GARAGE TOP PLATES NAILED AT 8" ON CENTER MAXIMUM ALLOWED 7" ON CENTER 3) BEDROOM 2 #2 SHEARWALL BLOCKS NOT NAILED 4) M/BR TOP AND BOTTOM PLATES NOT NAILED AT 7" ON CENTER ON #2 SHEARWALL ALSO DEN 5) BEDROOM 3 #3 SHEAR MID BLOCKS NOT NAILED