Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/30/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/29/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) CANNOT INSPECT INTERMEDIATES UNTIL STUCCO LATH APPROVED 2) STUCCO LATH NOT NAILED UNDER EAST 03040 WINDOW 3) STUCCO LATH NOT NAILED UNDER PORCH LEDGER AND RAKE RAFTER 4) STUCCO LATH NOT CAULKED AT A/C LINES AND GAS LINE AND CONDENSATE 5) PROVIDE ? TO NAIL STUCCO LATH AT PORCH 6) BACK GROUT FLOOR PENETRATIONS FOR PLUMBING 7) NAIL PROTECT 220 RANGE WITHIN 1 1/4" OF STUD SURFACE 8) TRUSS DRILLED HOLE AT WEST END OF SHEAR WALL BY WATER HEATER 9) PROVIDE CITY APPROVED TRUSS ENGINEER REPAIR |