Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/09/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* #1 1) TAPE 10-3 ROMEX ABOVE OUTLET. 2) CLOTHES WASHER OUTLET MISSING OR CANNOT BE ON KIT CIRCUIT. 3. NAIL ROMEX ABOVE CLOSET SW BEDROOM EVERY 4 1/2' AND WITHIN 12'' OF EACH BOX. 4) SMOKE DETECTORS TO BE IN BEDROOMS HAVE TO BE FINISHED. 5) BATHROOM LIGHT FIXTURE-MOVE DUCT AWAY FROM IT. 6) SMOKE DETECTORS TO BE AT 18' AWAY FROM CORNER IF CEILING MOUNTED AND 36" AWAY FROM REGISTAR. OR 9" DOWN FROM CEILING IF ON WALL. 7) NAIL PANEL FEEDER WHRE LOOSER OR EVERY 4 1/2'. #2 1) WHEREIS WH FEED? 2) NAIL ALL ROMEX EVERY 4 1/2' AND WITHIN 12'' OF BOXES. #3 PLAN SHOWS PANELS TO BE OUTSIDE BY SERVICE #4 PLANS HAVE BEEN REVISED, WH'S NOW OUTSIDE WASHER & DRYERS NOW INSIDE GET OK. #5 FHA STRAPS ON PANEL FEEDERS TO BE CORRECTED |