Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM02451
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2005 | FRAMING | Approved | ||
02/08/2005 | FRAMING | Partial Approval | ||
01/31/2005 | FRAMING | Approved | IVRS - Inspection :*A | |
01/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1 LADDER BACK MISSING KITCHEN SHORE WALL 2 PROVIDE APPROVED TRUSS REPAIR DOCUMENTS FOR 10 LOCATIONS |
|
01/18/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO LATH NOT COMPLETE AT POP OUTS. WINDOW NOT INSTALLED 2) NO DWV WATER TEST 3) SHEARWALL DBL TOP PLATE AT KITCHEN HAS BEEN CUT FOR RANGE DUCT. PROVIDE ENGINEERS APPROVED REPAIR 4) KITCHEN DWV VENT CANNOT RUN HORIZONTAL BELOW 6" ABOVE FLOOD RIM OF SINK 5) NAIL PROTECT WIRES AT KITCHEN SHEARWALL 6) 5 TRUSSES HAVE DAMAGED GANG NAILS, PROVIDE TRUSS ENGINEERS APPROVED REPAIR (10 LOCATIONS) |