Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM02433
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGES OK | |
03/11/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
03/10/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONTRACTOR HAS COVERED/CONCEALED PIPING BEFORE INSPECTION. INSPECTOR WILL NOT ACCEPT REMOVING INSULATION DURING INSPECTION. EXPOSE ALL PIPING AND FITTINGS FOR INSPECTION 2) NO TEST ON PVC 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4) VENT FITTINGS BELOW FLOOD RIM TO BE DRAINAGE FITTINGS 5) INSPECTION STOPPED |
|
03/03/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
02/28/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
12/15/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/1)YARDWATER CONNECTION AT BLDG OK TO COVER 2)MAY NOT USE PVC FEMALE THREADED FITTING FOR WATER PIPING | |
11/22/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 6" SDR 35 X 6" SCH 40 PVC SEWER CONNECTION OK. COVER. |