Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/28/2007 | PLUMBING - FINAL | Not ready for Inspection | ||
| 06/26/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. WORK HAS BEEN COVERED WITHOUT INSPECTION. LAUNDRY REMOVED KITCHEN NOT EXPOSED REQUIRE AVBS ON HOSE BIBS. 1. NO SIDE WALL CLEARANCE ON WATER CLOSETS. 2. ALL EXTERIOR WATER PIPING TO BE INSULATED 3. BATHTUB ON RAISED PLATFORM IS IT RATED FOR WEIGHT? |
|
| 06/06/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLUMBING INTERMEDIATE HAS NOT BEEN INSPECTED. WASHER OUTLET BOX HAS BEEN ADDED - NOT ON PLAN. ONE KIT SINK HAS BEEN REMOVED. EXPOSE CAPPED PLUMBING PIPING. EXPOSE NEW PIPING AT LAUNDRY & SINK EXPOSE CLEANOUTS AT LAUNDRY & SINK NEW WATER HEATER INSTALLED IN MIDDLE OF BUILDING WITH T&P TO FUNNEL DRAIN. THIS IS NOT ALLOWED. CLEARANCES FROM SIDE WALL TO WC NOT A MIN. OF 15" EXTERIOR WATER PIPING IS PVC EXTERIOR GAS PIPING IS NOT SUPPORTED, ROOF PENETRATIONS ARE NOT FLASHED. |