Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* C OF O TO BE ISSUED WHEN ALL INSPECTIONS FINALED (RIGHT OF WAY, ENGINEERING, LANDSCAPE) |
|
| 03/21/2007 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) FOR GAS CARD RETEST SYSTEM TO 10 PSI 2) PROVIDE APPROVED ELECTRIC FINAL 3) ALL PLANS MUST HAVE REGISTRANT SEAL AND CITY OF TUCSON APPROVAL STAMP (ELECTRICAL ALSO) |
|
| 06/26/2006 | BUILDING - FINAL | Denied | 1. PROVIDE SMOKE DETECTORS @ TOP OF INTERIOR STAIRS AND IN HALLWAYS LEADING TO BEDROOMS 2. PROVIDE FINAL ELEC & PLMG APPROVAL 3. GLAZING IN WINDOW @ STAIRWAY REQ'D TO BE TEMPERED IF LESS THAN 60" ABOVE WALKING SURFACE. 4. ONCE CONCEALED WORK ISSUES ARE RESOLVED, RESTORE OPEN WALL SURFACES. 5. PROVIDE BIRD BLOCKING/VENTING @ EAVE OUTSIDE OF REAR DOOR. |
|
| 06/06/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. UNABLE TO GO IN FOR BUILDING FINAL INSPECTION. 2. PROVIDE INSPECTION RECORD CARD WITH OTHER FINAL INSPECTIONS. 3. PROVIDE APPROVED PLAN FOR REMODEL. |