Permit: T04CM02396

Parcel: 136405000

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T04CM02396

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/24/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
09/22/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) WIRES MUST BE MINIMUM 1" FROM BOTTOM OF EXHAUST AND 3" MINIMUM CLEARANCE FROM TOP OF FIREPLACE VENT 2) SUPPORT AB'S IN SECOND FLOOR MORE FREQUENTLY 3) PEX AT LEAST 6" FROM B-VENT 4) HALL VENT HAS REVERSE SLOPE ON SHOWER DRAIN 5) FIREPLACE VENT NEEDS EACH SECTION SUPPORTED 6) SEE INSTALLATION BOOK 7) 1" CLEARANCE TO B-VENT