Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) TRUSS REPAIR NOT NAILED BETWEEN 8 AND 9 OR BELOW 7 AND NOT BEARING AT POINT 14 2) CHIMNEY CHASE CANNOT BEAR ON OSB MUST BE CLIPPED AT 4 CORNERS TO ROOF STRUCTURE 3) OK TO DRY IN DO NOT COVER FP CLIP OR TRUSS REPAIR | |
| 09/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) A-1 3 PT BEARING TRUSS NOT BEARING AT MID-POINT 2) A-2 TRUSSES NOT 3 PT BEARING 3) A-8 NOT BEARING MID-POINT 4) SW5 MISSING ANCHORS BEHIND FURNACE 5) GARAGE HOLDOWN AT SW5 NOT CONNECTED TO SHEARWALL 6) 4 X 6 POST MISSING REAR PORCH 7) PROVIDE CHIMNEY FRAME PLAN FOR AS BUILT WITH POSITIVE CONNECTION TO STRUCTURE |