Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/11/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) BLOCK AROUND HVAC DUCTS AT GARAGE 2) MAINTAIN SUPPORT FOR H20 HEATER, UNDER OSB AT PLATFORM 3) HAVE SPRINKLER SYSTEM INSPECTED BY FIRE DEPARTMENT 4) NORTH BATH CAN LIGHT FLEX ELECTRIC TOUCHING CU. H20 LINE 5) NORTH EAST BATH OVERSPAN STUD SPACE, AT TOILET 6) DON'T LET CONDENSATE/T & P TERMINATION GET BURIED, THEY NEED A DRY WELL 7) PRESSURIZE H20 LINE 8) NEED A H20 BOND 9) NOTES FROM LAST INSPECTION NOT IN PLAN TUBE-DWV NO H20 TEST 10) BACKING VERT REFRIG/AREA INSIDE CORNER, F/BLKS MISSING 11) APPROVAL ON HANGER 12) FIRE PLACE CAULK AT LOG LITER PIPE 13) NAIL AND STRAP CANTILIEVER BEAMS 14) WET VENTING IS ONLY ALLOWED FOR TRAP ARMS SEE DRAWING FRONT PAGE, HALL BATH 15) FIRE BLOCK LID F/PLACE MASTER BED, DOES F/PLACE GET A LOW VOLTAGE CONTROL WIRE ? 16) LOOSE OUTLET MASTER BEDROOM 17) MASTER WINDOW CHECK GLASS 18) MISSED TWO H.D. 19) OUTLET JACUZZI ACCESS PANEL 20) LAV VENT 6" ABOVE FLOOD RIM 21) MISSED TWO H.D. N/BEDROOM (12) TOTAL |
|
| 03/30/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |