Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : ROWS OF ROOF NAILING MISSING - CHECK ALL OSB COVERING ONLY 1 TRUSS BAY MUST BE BLOCKED AND NAILED OSB LESS THAN 24" WIDE MUST HAVE H CLIPS SOME ROOF OSB DOES NOT LAND ON TRUSSES AT EDGES STRAP DOWN 1/2 GABLE TRUSS AT GARAGE REAR CLIP WALK DECK LEDGER & ENTRY ROOF LEDGER SOLIDLY BLOCK PATIO COLUMN BOTTOM PLATES CLIP STUDS 2ND FLOOR REAR & FRONT LEFT CORNER CLIP HIP TRUSSES FINISH NAILING MASS AT GARAGE & DIAGONAL BRACING |
|
| 07/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |