Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/26/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 08/26/2004 | FRAMING | Denied | 1) 1" CLEARANCE REQUIRED BETWEEN "B" VENT AND COMBUSTIBLE MATERIAL 2) OVER SPAN ABOVE POT SHELF 3) 6/D3 NOT COMPLIED WITH AT DBLE SHEAR WALL #1 4) ANCHOR BOLTS LOOSE OR MISSING ON SHEARWALLS 5) DBL TOP PLATE THRU CUT BY A/C CABLE 6) FHA STRAPS REQUIRE 6-16D NAILS ON EACH END 7) DUCTS RESTRICTED LIVING ROOM POT SHELF TO TIGHT OF BEND | |
| 08/25/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) GABLE AREA ABOVE GARAGE NOT DONE 2) YARD WATER LINE MOVED 3) NAIL PROTECT TRP LINE 3) SHEAR #5 AT GARAGE NOT PER SCHEDULE AND PROVIDE STUD SHOE AT OVER BOARDED STUDS 4) 5D3 NOT PER PLAN 5) COMPLY WITH KEY NOTE: #6 ELEV 6) STOPPED INSPECTION |
|
| 08/24/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 08/23/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |