Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM02345
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/07/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
10/06/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PLATFORM AT FAU MISSING BLOCK NOT NAILED 2) FAU SECONDARY PAN HAS BLOWN INSULATION IN IT 3) KNOCK OUT MISSING AT PANEL |
|
10/05/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL KNOCKOUT AT MAIN PANEL 2) ARC FAULT CIRCUITS NOT LABELED 3) EAVE VENT WESTSIDE BLOCKED WITH INSOLATION 4) EXHAUST FAN IN HALL BATH INOPERATIVE 5) FAU SPARK PLATE NOT INSTALLED PER MANUFACTURER INSTALL INSTRUCTION 6) FAU DOOR WON'T SECURE 7) PLATFORM NOT NAILED NEEDS BLOCK |
|
10/04/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO GAS BOND 2) ELECTRIC SERVICE PANEL MISSING DEAD FRONT SCREW 3) SECURE A/C FLEX WITHIN 12" OF DISCONNECT-WEATHER TIGHT NUTS LOOSE 4) ISLAND REQUIRES GFCI OUTLET. OUTLET NOT ALLOWED UNDER COUNTER OVERHANG 5) FURNACE GAS LINE NOT CONNECTED 6) FURNACE SPARK SHIELD NOT PROPERLY INSTALLED 7) PROVIDE FURNACE INSTALLATION MANUAL 8) GARAGE DOOR NOT SELF CLOSING |