Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM02344
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/07/2004 | FRAMING | Approved | IVRS - Inspection :* | |
08/05/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 2) ROD HEAD ANCHOR BOLTS LOOSE 3) NO DWV WATER TEST 4) PROVIDE 1" CLEARANCE TO COMBUSTIBLES AT W/H VENT |
|
08/04/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HOUSE INSULATED BEFORE INSPECTIONS 2) REMOVE INSULATION |