Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2004 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 08/17/2004 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CHECK ALL SHEARWALLS GYP BD SHALL LAP MINIMUM 3/4" ON TO BOTTOM PLATE 2) NAILS SHALL BE 3/8" MINIMUM FROM GYP EDGE |