Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM02327
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2004 | PLUMBING - INTERMEDIATE | Approved | ||
07/28/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*NOT READY. (1) CO MISSING AT NEW SINK. (2) PROVIDE ACCESS TO RELIEF LINE AND PAN DRAIN | |
06/25/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ OK TO COVER WALLS. PLEASE PROVIDE APPROVED CLEVOS HANGERS AT EXPANSION TANK. ALSO WILL SEE TERMINATIONS OF RELIEF AND PAN DRAIN AT FINAL | |
06/21/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ NEED TO SEE RELIEF LINE AND PAN DRAIN TERMINATION. PLEASE PROVIDE STAMP ON LETTER FROM ARCH. TO DELETION OF ICE MAKER. ALSO PLEASE ANCHOR EXPANSION TANK BEFORE FINAL. PLEASE INSTALL AS PER PLAN OR PROVIDE APPROVED REVISED PLAN. | |
06/10/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) PROVIDE WTR TEST THRU ROOF ON WASTE AND VENT PIPING AND EXPOSE ALL WASTE AND VENT FITTINGS. 2) INSTALL H20 PIPING PER PLAN. 3) REMOVE CONDENSATE TIE IN AND CONNECT VENT USING GLUE STYLE COUPLING. 4) ICE MAKER MAY REQUIRE TESTABLE BACKFLOW DEVICE OR PROOF OF 1" AIR GAP. |