Permit: T04CM02265

Parcel: 117080300


Addresses:

821 S 3RD AV


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM02265

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/27/2005 FRAMING Approved IVRS - Inspection :*
04/25/2005 FRAMING Partial Approval IVRS - Inspection :*
1) SEE #5 DATED 4/21/05
2) OK TO INSULATE AND ROCK
04/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 3" ABS VENT MUST PENETRATE ROOF 6" ABOVE
2) PEX LINE 12" AWAY FROM CAN LIGHTS
3) NO TEST ON DWV'S
4) GROUND METAL BOXES
5) DRYER VENT EXCEEDS 25 FT RUN
6) GAS TEST AT 9 PSI MUST HOLD AT 10 PSI
03/29/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999* REVISE DRAWINGS TO REFLECT AS BUILT
11/24/2004 FRAMING Partial Approval PARTIAL ROOF TRUSS ONLY
11/08/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*