Permit: T04CM02265

Parcel: 117080300


Addresses:

821 S 3RD AV


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T04CM02265

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
11/24/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
11/17/2004 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*/REMOVE DIRT FROM UNTREATED JOIST
11/09/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) EXPOSE PLUMBING WHERE INDICATED
2) EXPOSE FTG AND HAVE PACHO METER TEST BY TESTING LAV TO CONFIRM REBAR IN FTG'S AND WALLS
11/08/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) EXPOSE ALL FOOTINGS AND FOUNDATION TO A DEPTH OF 12" AND PROVIDE PROOF OF REINFORCING STEEL
2) UNTREATED WOOD IN FLOOR JOIST IN CONTACT WITH SOIL OR TO CLOSE PER CODE. REMOVE ALL FLOOR SHEATHING
3) REINFORCING STEEL CANNOT BE IN CONTACT WITH SOIL
4) PORCH FOOTINGS NOT PER 1/3
5) TRUSS T-25 MISSING "T" BRACE
6) TRUSS T-14 HAS BEEN SCABBED. PROVIDE APPROVED REPAIR DOCUMENT
7) STOPPED INSPECTION. TOO MANY ITEMS