Permit: T04CM02257

Parcel: 130112520

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/24/2007 BUILDING - FINAL Approved IVRS - Inspection :*
10/23/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS 9:10 AM
10/18/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MOVE OUTLET FROM BEHIND RANGE TO COUNTER TOP
2) OUTLET MISSING AT OPEN BOX MASTER BEDROOM
3) PAINT ABS ROOF VENTS WITH LATEX PAINT
4) VACUUM BREAKER MISSING AT HOSE BIB
5) FLEX NOT ALLOWED ON PTR LINE
6) CUT CLEANOUT FLUSH WITH GRADE
7) 1" CLEARANCE REQUIRED FROM COMBUSTIBLE AT WATER HEATER B-VENT
07/03/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*