Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 08/23/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) LOCKED GATE, NO ACCESS |
|
| 08/20/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED 10' HEAD TEST ON PLUMBING |
|
| 08/18/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO DWV WATER 2) LEAK UNDER FLOOR |
|
| 08/17/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO DWV WATER TTEST PER UPC SECTION 712.2 2) PORCH FOOTING AND SLAB OK TO POUR |
|
| 07/12/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ 1) ROUGH TO OUTSIDE FOUNDATION OK 2) CLEANOUTS, SEWER LINE AND CONNECITON NOT READY | |
| 07/09/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO DWV 10 FOOT WATER TEST 2) PLUMBING MUST BE 12" BELOW GRADE AT EXIT OF BLDG OR PLUMB IN METAL |