Permit: T04CM02196

Parcel: 12801011A


Addresses:

302 S WILMOT RD


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T04CM02196

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
08/08/2005 EXCAVATION/LAYOUT REBAR & ZON Approved
07/05/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* 1) OK TO PLACE NORTH ABUTMENT. 2) YOU MUST HAVE SPECIAL INSP. REPORTS ON SITE.
06/30/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) PROVIDE INFORMATION ASKE D FOR 2) DO NOT POUR CONCRETE WITHOUT APPROVAL FROM COT. 3) YOU MUST HAVE SPECIAL INSPECTION REPORTS ON SITE.
06/29/2005 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :* PROVIDE INFO REQUESTED BEFORE PLACING CONCRETE.
06/28/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* 1) CONTRACTOR WANTS TO WET SET WALL D?? PROVIDE LETTER FROM ENGINEER ALLOWING THIS.
06/27/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* ENGINEER TONY @ SCI DESIGN NOTES 15" IS L? LENGTH ??TIES PER AASHTO; 16" GIVEN, STIRRUPS AND ABUTMENT STELL OK. WING WALL EXT AND END WALL EXTENSIONS NOT YET IN.
06/23/2005 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :* NO NEW WORK READY. NO PLANS ON SITE.
06/22/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* CAISSONS COMPLETE FOR ABUTMENTS & ?WALLS
06/21/2005 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
06/20/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* REMAINING 3 SOUTH CAISSONS OK TO POUR.
06/17/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* PLACEMENT PER SPEC'S OK 2 EACH BRIDGE & 1 WING CAISSON BOTH SIDES
06/16/2005 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
06/15/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
06/15/2005 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
06/10/2005 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) PRE-INSPECTION FOR CAISSON STEEL
2) SIZE AND TIEING OF CAISSON STEEL OK
3) RECALL INSPECTION WHEN FOOTINGS DRILLED AND STEEL STARTS BEING PLACED