Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM02159
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/29/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) NEED RAT RUN ON TRUSS RT6 2) WEST SIDE OUT RIGGER CUT TO WIDE, FILL IN GAP SUPPORT BELOW 3) USE LONG NAILS IN LUS26 HANGERS FOR DOUBLE SHEAR SEE PAGE 73 USP BOOK 4) WRONG SIZE HEADER AT WEST REAR 5) 2 NAILS IN ALL WIND BRACES 6) MISSING NAILING ON ROOF, MARKED IN BLACK 7) INSTALL 3 DRAG STRUTS AT GARAGE FRONT 8) INSTALL BACKING FOR FLASHING, ROOF ENTRY TOWER 9) TOE ? JACK RAFTERS AT ROOF GARAGE, HANGERS PUT ON SHEET ROCK CARRYING MEMBER |