Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T04CM02151

Parcel: 141173610

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/19/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/16/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
07/14/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FRONT HIP NOT NAILED OFF 2) MISSING ROOF NAILING 3) FINISH INSTALLING ROOF PLY 4) TWO NAILS IN EACH WIND BRACE 5) BLOCK BEARING SIDE OF TOWER, 2 X 4 ON EDGE TILTED NOT SUPPORTING ROOF LOD, TOWER FRAMING MANY ISSUES 6) NAIL FREEZE BOARDS AT ROOF DECK 7) DBL STUD UNDER GIRDER 8) INSTALL TRUSS BRACING PER CALC'S