Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/11/2005 | FRAMING | Approved | IVRS - Inspection :* 1) COMPLETE WATER HEATER DOOR FRAMING |
|
| 03/09/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 03/02/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) EXISTING BATHROOM, CEILING LIGHT FIXTURE ROMEX PULLED TO TIGHT, SECURE ROMEX 6" OF BOX, UNSHEATHED WIRE OUTSIDE BOX 2) NEED A 12 GAUGE WIRE 20 AMP CIRCUIT FOR BATH/OUTLET/RECEPTACLE 3) NAIL PROTECTION MISSING THRU OUT BATHROOM 4) BEAM BEARING FROM OTHER SIDE OF WALL, STUDS BELOW NOTCHED TO DEEP 5) ROOF RAFTERS DRILLED HOLES TO BIG NEED ROOF SUPPORT OR SISTER A BIGGER RAFTER 6) WALL BACKING MISSING EACH SIDE OF TOILET COMPARTMENT 7) OLD CEILING ELECTRIC IN BOX STILL HOT ? 8) NEW CEILING ELECTRIC WHERE DO EXISTING WIRE COME FROM ?, TOO MANY WIRES IN BOX 9) OUTLET AT TOILET NOT FASTENED TO WALL 10) TUB NOT INSTALLED, NO WATER TEST 11) TUB VENT BEFORE GOING HORIZONTAL WITH TUB VENT NEEDS TO BE 6" ABOVE FLOOD RIM TUB BLOCK OUT TO HAVE CONCRETE 12) NO DOOR FRAMING 13) NEED T & P LINE FOR H20 HTR 14) BEDROOM SOUTH OF BATH NOT DUCT FOR HVAC ------------------------------------------------------------------------------------------------- NEW ADDITION: 1) ? TUB DOES IT HAVE A TRAP ?, NEEDS H20 TEST 2) CHECK ALL BANG PLATES 3) #12 ROMEX HANGING FROM SHOWER CEILING 4) ROMEX IN CLOSET CEILING NOT IN A BOX 5) POCKET DOOR NOT SECURED 6) NEW H20 HTR T & P AT GARAGE 7) EXHAUST FANS CLOSET/GARAGE NOT ON PLANS 8) RAN OUT FO ROOM NOT READY FOR INSPECTION |