Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM02109
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/01/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) COVERED DRAG STRUTS GARAGE FRONT WITH LATH 2) RAT RUN NOT IN STALLED 3) INSTALL SUPPORT BLKS FOR TOWER WALLS BEAR BETWEEN RAFTERS ON OSB | |
06/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) WIND BRACES EAST 2) RAT RUN 3) DRAG STRUT AT GARAGE 4) TRUSS BEARING PT AT DIAGONAL WALL 5) MISSED PA S/WEST CORNER 6) BLOCKS TO SUPPORT FRONT ENTRY BETWEEN TRUSSES 7) SHIM ALL 3 PT TRUSSES | |
06/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) MISSING NAILING ON ROOF 2) DRIVE OR REMOVE ALL NAILS AND STAPLES ABOVE ROOF DECK PLANE 3) TWO NAILS IN ALL WIND BRACES 4) P.A. MISSED SHEAR REAR WALL WEST 5) NAIL ALL FRIEZE BOARDS TO ROOF 6) NAIL ALL SHEAR PANELS TO ROOF 7) AT STRAPS PER PLAN DRAG STRUTS AT GARAGE SHEAR 8) TWO WIND BRACES AT WEST WALL 9) MISSED PA STRAP AT FRONT SHEAR EAST 10) ADD BLKS TO SUPPORT ENTRY ROOF 11) BEARING PTS AT DIAGONAL WALL MISSED P.T. LOADING 12) SHIM ALL 3 PT TRUSSEES 13) MISSING MAIN LATERAL BRACE |