Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM02098
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2004 | FRAMING | Approved | IVRS - Inspection :* | |
08/25/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) SEE NOTE #2 2) PROVIDE APPROVED REPAIR FOR JACK HAMMERED POST TENSION FOR UNDERGROUND PLUMBING REPAIR 3) SEE INSPECTION DATED 7/29/04 | |
07/09/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) PENDING LSI REPORT FOR CABLE INSPECTION 2) OK TO INSULATE | |
07/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BROKEN 2" SEWER LINE AT KITCHEN AREA, LEAVE EXPOSED FOR TESTING 2) PROVIDE LSI REPORT FOR EXPOSED CABLES |
|
07/07/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CHECK STAPLE SPACING AND BAY WINDOW 2) NO TEST ON DWV'S WATER LINES OK |
|
07/06/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) RED HEAD A.B.'S LOOSE 2) NO DWV WATER TEST 3) HOLDOWN BOLTS LOOSE |