Date Description Inspector Results Comments
07/23/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/20/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :SEE LAST INSP
07/15/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) BEARING PT ON SLAB, WEST WALL, FOUNDATION, MAKE BEAM LONGER CONE IS BROKEN 2) INSTALL HANGER AT GLU LAM WEST WALL 2) TWO NAILS IN ALL WIND BRACES AT PLATES 3) SNUB NOSE TRUSSES, 3PT BEARING REQUIRED SHIMS
07/14/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*/ 1) TWO NAILS PER WIND BRACE, BOTTOM-TOP PLATE 2) NAIL SHEAR TRANSFER GARAGE SHEAR TO ROOF 3) AT R1XA GAP BETWEEN BRACE AND VERTICAL MEMBER
07/12/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) NO PLANS/PERMIT