Permit: T04CM02076

Parcel: 125074580


Addresses:

2709 E 8TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/15/2005 FRAMING Approved IVRS - Inspection :*
01/04/2005 FRAMING Partial Approval IVRS - Inspection :*
1) FRAMING TO BE APPROVED WHEN BREAK THROUGH TO TV IS INSPECTED
2) OK TO INSULATE
12/29/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETED
2) COMPLETE OPENING TO TV ROOM
3) HAVE GAS REVISION FOR USE OF CORRIGATED GAS LINE
4) PROVIDE PRESSURE TEST TO GAS LINE
5) PROVIDE TEST UNABLE TO LOCATE GAUGE
12/21/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CEILING LIGHT WIRES MUST TERMINATE IN APPROVED BOXES
2) PROVIDE A DRAIN WASTE VENT WATER TEST TO ROOF PER UPC
3) BREAK THRU TO EXISTING HOUSE NOT MADE
4) SMOKE DETECTOR REQUIRED IN FOYER LEADING TO BEDROOM AND IN BEDROOM
5) INSULATE ALL DUCT "Y" IN CONFINED SPACE
6) DUCTS RESTRICTED BY SHARP ? AND FRAME AND BY OUTSIDE UNIT
7) HAVE GAS PLAN REVISED FOR USE OF CORRIGATED STAINLESS STEEL PIPE
8) NAIL POST CAPS
9) WATER HEATER VENT MUST EXTEND 1 FEET HIGHER THAN VERTICAL WALL SURFACE WITHIN 10 FEET
10) NO GAS PRESSURE TEST LOCATED
11) STOPPED INSPECTION, TO MANY ITEMS