Permit: T04CM02074

Parcel: 13355231A

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/02/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ 1) WATER TEST 10 PSI IN WALL AND OVERHEAD OK 2) WASTE AND VENT WATER TEST THRU ROOF ON CORRECTION OK
07/01/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ WASTE AND VENT THRU ROOF WTR TEST OK. EXCEPT WORK ROOM HAND SINK TO HAVE CLEAN OUT ON VERTICAL.
06/28/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*