Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T04CM02074

Parcel: 13355231A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/22/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/ CORRECTION MADE WTR TEST UNDERGROUND.
06/21/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ 1) WATER TEST PARTIAL 3" DRAINAGE ON NORTH WALL OK. 4" DRAIN TO RESTROOM OK 2) PROVIDE 4" FULL SIZE CLEANOUT PER PLAN IN RESTROOM 3) HAVE RED LINE DRAWINGS ON SITE AND REVISED CITY APPROVED PLAN AT LATER DATE OF YOUR INSTALL 4) PROVIDE APPROVED COUPLINGS ON 4" DRAIN TIE IN 4) NO THREADED FITTINGS BELOW SLAB OR IN UNACCESSIBLE AREA