Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/03/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection :*/ 1) POST YOUR ADDRESS AND LOT NO. 2) SEWER/HCS OK TO COVER. 3) ABS DWV UNDERGROUND OK TO COVER. COPPER LOOPED OK. WTR TEST ONE RISER TO TEN FT. |