Permit: T04CM02054

Parcel: 138133350

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/29/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/24/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAIL PROTECT PLUMBING FROM OUTSIDE 2) HOLDOWN AT SGD NOT NAILED 3) COMPLY WITH DETAIL 7SD3 4) STRAPS FROM 1ST TO 2ND FLOOR MISSING OR NOT NAILED 5) COMPLY WITH DETAIL 10 AND 11 SD4 6) COMPY WITH DETAIL 1SD3 EDGE NAILING 7) REPLACE SHEAR PANEL AT SOUTH WEST CORNER 2ND FLOOR 8) OVER SPAN GARAGE WEST WALL