Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE. 3) OK TO BACKFILL TRENCH | |
| 12/15/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)CAN NOT LOCATE A 1/4 BEND IN A HORIZONTAL POSITION ON TUB TRAP ARMS. THESE MUST BE L-SWEEPS 2)RE TEST THE SYSTEM |
|
| 12/10/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)CAN NOT WET VENT A 2" TRAP ON A 2" BARREL. THE BARREL SHALL BE AT LEAST ONE PIPE SIZE LARGER THAN TRAP ARM ON EAST UNIT 2)NOTE: WEST UNIT IS OK FOR BACKFILL ONLY |