| 07/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/09/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED COPY OF PREVIOUS PAPERWORK DENIAL TO CHECK FOR RE-INSPECT |
|
| 07/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SHEARWALL #4 NAILING 2"-12" PATTERN 2) INSTALL BOLTS IN HOLDOWNS 3) INSTALL CMST 14'S PER PLAN 4) INSTALL PIPE POST TO SUPPORT G.L.B. 5) SET NAILS/STAPLES FLUSH WITH OSB 6) NEED LADDER TO ACCESS UPPER ROOF 7) INSTALL SIMPSON CS20 PER DETAIL 19 PAGE 3.3 8) STOPPED INSPECTION 9) CHECK STAIRS FOR 3/8" MAXIMUM DIFFERENCE IN RISE 10) REPAIR ALL EXCESSIVELY CUT HOLES IN SHEARWALLS 11) WIND BRACING REQUIRED ALL CORNERS EACH WAY AND MAXIMUM 25' OF RUN |