Date Description Inspector Results Comments
06/21/2004 FRAMING Approved IVRS - Inspection :*
06/18/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 5/D3 AND 3/D3 NOT COMPLIED WITH AT SHEAR WALL
06/17/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SEE LAST INSPECTION 2) MECHANICAL NOT COMPLETE 3) CONDENSATE LINES NOT INSTALLED
06/16/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ANCHOR BOLT MISSING GARAGE EAST WALL 2) 5/D3 NOT COMPLIED WITH GARAGE #5 SHEARWALL 3) RED HEAD ANCHORS LOOSE 4) 1/2" CLEARANCE REQUIRED BETWEEN SCISSOR TRUSS AND NON BEARING WALL 5) SHEAR WALL STUD AT BACK OF HOUSE OVER NOTCHED 6) REAR SHEAR 7) HOSE BIB BENT 8) TUB VENT OUT OF WALL 9) PROVIDE ENGINEER APPROVED DETAIL FOR SHEARWALL TRANSFER BETWEEN DROP CEILING AND BOTTOM CHORD OF TRUSS AT DOUBLE #1 SHEARWALLS 10) FIRESTOP KITCHEN CHASE 11) NO DWV WATER TEST