Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/04/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE ROMEX 6" FROM BXOES 2) BANG PLATES THROUGHOUT ROMEX 3) LOOSE FURRING STRIPS BEDROOM #4 4) BEDROOM 4 WINDOW SILL HEIGHT EXCEEDS 44" 5) BEDROOM #5 SMOKE WITHIN 12" OF REGISTER 6) SECURE 90 DEGREE VENTS THRU ROOF 7) FIRE BLOCK AT HOME RUNS ABOVE SUB PANEL. REVISE PLAN TO SHOW SUB-PANEL LOCATION OR INSTALL TO PLAN 8) BEDROOM #2 WINDOW SILL HEIGHT EXCEEDS 44" 9) EXISTING BATH #2 REPAIR TOP PLATE PLUMBING WALL OVER NOTCHED 10) OVER NOTCHED STUD EXISTING BATH #1 SISTER STUD NEEDED 11) INSTALL DIVERTER EXISTING BATH #1, FIREBLOCK DROPPED CEILING AND BLOCK REGISTER 3 SIDES |
|
| 07/31/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 07/29/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) BLOCK REGISTERS 3 SIDES 2) LOOSE FURRING MISSING FURRING THROUGHOUT 3) NAIL PROTECT THROUGHOUT 4) GROUND METAL BOXES 5) REINFORCE WINDOWS 4 CORNERS-SECURE WEST WALL 6) COVERED SHEETROCK REMAINS ? ROOMS-CLEAR DEBRIS 7) STOPPED INSPECTION |
|
| 07/26/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COVERED WITHOUT INSPECTIONS-EXPOSE 2) REINFORCE ALL WINDOWS 3) SEAL PENETRATIONS 4) PROPERLY SECURE LATH WEST MASONRY WALL |
|
| 07/14/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 07/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLY WITH PREVIOUS INSPECTION 2) NO ELECTRICAL INSTALLED |
|
| 07/06/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :*COMPLETE STUCCO MESH PRIOR TO INTERMEDIATE INSPECTIONS |