Permit: T04CM01957

Parcel: 141145700

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/28/2004 FRAMING Approved IVRS - Inspection :*
06/18/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) HOLDOWNS NOT NAILED TO DOUBLE KING STUDS 2) 2 X 6'S NOT BEARING, ON BOTTOM PLATE AND TO SHORT TO TOP PLATE 3) OVER SPAN 2 X 6 WALL SOUTH EAST CORNER SHOULD BE 16" ON CENTER 4) COMPLY WITH DETAIL S2-1 AND S2-2 5) HOLDOWNS NOT PER DETAIL ON PLAN
06/16/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) EXTEND J-BOX FLUSH WITH FINISH WALL (OLD LIGHT) 2) FINISH FRAMING AT EXISTING WALL 3) TIE NEW ROOF TO EXISTING, LAG TRUSS CHORD TO OLD WALL