Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2005 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 12/09/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CARPORT AND PORCH MASONRY COLUMNS OK TO GROUT TO 48" HEIGHT 2) ?, LAY BLOCK TO TOP OUT AND INSTALL REBAR 3) RECALL PRIOR TO GROUTING |
|
| 11/12/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) MAIN HOUSE OK TO 8'-8" TOP OUT (OK TO GROUT) 2) CARPORT 2 WEST PIERS 48" LIFT OK TO GROUT 3) CARPORT 1 SOUTHEAST PIER 48" LIFT OK TO GROUT 4) CARPORT NORTH EAST PIER AND 2 PORCH PIERS NOT READY YET FOR 48" LIFT INSPECTION |
|
| 11/09/2004 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :*/ 1) CANCELLED PER PAPERWORK TURNED IN BY R. OHAVER | |
| 11/05/2004 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BOND BEAM REINFORCING STEEL MUST BE AT LEAST 1 1/2" BELOW TOP OF BOND BEAM 2) COLUMNS NOT READY |
|
| 10/21/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/1)1ST 48" LIFT MAIN HOUSE & CARPORT OK 2)2-FRONT PORCH PIERS NOT READY |