Permit: T04CM01908

Parcel: 133369570

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM01908

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)PLBG FINAL IS OK 2)OK FOR C/O
10/04/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) NEED COMPLETE TEST ON GAS LINE. MANIFOLD AT FIXTURES NEED TO SEE GAS SOLINOID VALVE. ABOVE CEILING WITH LABEL FOR VALVE 2) NEED YOUR REVISED PLAN AS PER 8/3/04 3) CODE VIOLATION AT 3 COMP-SINK. INSTALL 2" FLOW CONTROL 4) NEED BACKFLOW DEVICE FOR ICE MAKER AND TESTING ON ALL OTHER DEVICES 5) THIS IS NOT COMPLETE ENOUGH TO INSPECT