Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM01908
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2004 | PLUMBING - INTERMEDIATE | Approved | ||
08/05/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) PLEASE PROVIDE REVISION ON P-8 IN COOLER 2) FIX STAND PIPE AT LAUNDRY (WASHER) 3) INSTALL RELIEF LINE 4) CAP OFF STUB FOR COOLER AT VALVE 5) TEST OK SILENOID NOT INSTALLED | |
08/03/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE PRESSURE TEST ON H20 SYSTEM 2) WASTE AND VENT NEED 4" VENT THRU ROOF PENETRATIOJN UP THRU ROOF MINIMUM HEIGHT REQUIREMENT 3) NEED MID SPAN SUPPORTS ON WASTE VENT 4) NEED CORRECT DRAINAGE AT ISLAND SINKS WITH TEST 5) OVERHEAD VENTS NEED APPROVED HANGERS AT CORRECT DISTANCES 6) NEEDS MINIMUM 10 PSI AIR TEST AT TIME OF INSPECTION |
|
08/02/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE COMPLETION OF WORK AND AIR OR WATER TEST ALL PIPING |