Permit: T04CM01908

Parcel: 133369570

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM01908

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/02/2004 PLUMBING - INTERMEDIATE Approved
08/05/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) PLEASE PROVIDE REVISION ON P-8 IN COOLER 2) FIX STAND PIPE AT LAUNDRY (WASHER) 3) INSTALL RELIEF LINE 4) CAP OFF STUB FOR COOLER AT VALVE 5) TEST OK SILENOID NOT INSTALLED
08/03/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PROVIDE PRESSURE TEST ON H20 SYSTEM 2) WASTE AND VENT NEED 4" VENT THRU ROOF PENETRATIOJN UP THRU ROOF MINIMUM HEIGHT REQUIREMENT 3) NEED MID SPAN SUPPORTS ON WASTE VENT 4) NEED CORRECT DRAINAGE AT ISLAND SINKS WITH TEST 5) OVERHEAD VENTS NEED APPROVED HANGERS AT CORRECT DISTANCES 6) NEEDS MINIMUM 10 PSI AIR TEST AT TIME OF INSPECTION
08/02/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PROVIDE COMPLETION OF WORK AND AIR OR WATER TEST ALL PIPING