Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2004 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 12/08/2004 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BONDING BUSHING REQUIRED ON RISER-CONNECT BOND BUSHING TO CUSTOMER SIDE GROUND BAR 2) PUT ADDRESS ON SERVICE PANEL |