Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 08/03/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection :* |
| 06/25/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection :*/ 1) MAIN ADDITION OK TO POUR 2) PATIO NOT READY |
| 06/23/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PLAN CALLS FOR 2-#4 REBAR HORIZONTAL IN FTG. 2) OVERLAP #4 REBAR MINIMUM 30 BAR DIAMETER 3) ISOLATE REBAR DRIVEN INTO GROUND FROM HORIZONTAL STRUCTURAL REBAR 4) WORKING ON GAME ROOM-FTGS INCOMPLETE 5) PORCH NOT STARTED |