Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01900
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2004 | FRAMING | Approved | IVRS - Inspection :* | |
06/21/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. Reverse pitch on condensate lines. No plans or permits on site. All chase fire stops require 2 layers of 1/2 osb. Red head anchor bolts loose on shearwalls. House drywalled without approval. Stopped inspection, all repeat items |
|
06/18/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ITEMS NOT CORRECTED |
|
06/17/2004 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925*. Install cripple studs/shims above 6050 header in living room. Top plates sagging straighten. Chase fire stop requires 2 layers of 1/2" osb. Red head anchor bolts loose on shear walls. Support condensates at 4' on center with 1/4"/ft pitch |
|
06/16/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BANG PLATE ABS AT BOTTOM PLATE IN HALL BATH 2) FIREPLACE NOT COMPLETE 3) FINISH CONDENSATE DRAIN INSTALL |