Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM01900
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/04/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) #4 NOT DONE |
|
06/03/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) REMOVE WINDOW FLASHING PAPER TO SEE HEADER STRAPS 2) NO CORRECTIONS MADE |
|
06/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
06/01/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
05/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ROOF NAILING MISSED ON WEST GARAGE PLANE 2) STRAP HEADERS WHERE NEEDED 3) RE-NAIL SHEAR PANELS WHERE NAILS SHOT TO DEEP 4) FHA STRAP BOTTOM PLATES AT PLUMBING CUTS |
|
05/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) MANY ROWS OF ROOF NAILING MISSING ROOF INSPECTION NOT DONE 2) SHEAR WALLS NOT COMPLETE 3) CLIP INSPECTION NOT DONE |