Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 09/24/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FRONT ENTRY STUCCO AND WEEP SCREED REMOVED 2) #22 BREAKER NOT A SQUARED AND NOT INDENTIFIED 3) SEAL KNOCK OUT AT DEAD FRONT 4) PAINT PVC AT IRRIGATION 5) EXHAUST FAN EAST WALL FLAPPER STUCK IN OPEN POSITION, THE ONE BELOW IS SEALED WITH STUCCO 6) SEAL OPENING AT GARAGE OPENER STUB OUT 7) HALL BATH GFI MISSING COVER PLATE 8) FAU, IN ATTIC, DOES NOT HAVE THE 30" OF WORKSPACE IN FRONT, FRONT COVER WON'T CLOSE, SPARK PLATE MISSING, PAN DIRTY |
|
| 09/22/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ALL REQUIRED INSPECTIONS MUST BE APPROVED BEFORE FINALS |