| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/25/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HOLDOWNS TO BE AT EACH END ALL SHEARWALLS WHERE INDICATED ON PLAN 2) SHEAR WALL DEN TO CARRY ALL THE WAY TO WINDOW FORM GARAGE 3' MAN DOOR 3) BLOCKING NOT NAILED SEVERAL PLACES ON ROOF SHEATHING 4) SHEAR WALL ANCHOR BOLTS NOT PER PLAN 5) INSTALL NAIL PROTECTION EXTERIOR BOTTOM PLATES AT PLUMBING CUTS |