Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/27/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/25/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) HOLDOWNS TO BE AT EACH END ALL SHEARWALLS WHERE INDICATED ON PLAN 2) SHEAR WALL DEN TO CARRY ALL THE WAY TO WINDOW FORM GARAGE 3' MAN DOOR 3) BLOCKING NOT NAILED SEVERAL PLACES ON ROOF SHEATHING 4) SHEAR WALL ANCHOR BOLTS NOT PER PLAN 5) INSTALL NAIL PROTECTION EXTERIOR BOTTOM PLATES AT PLUMBING CUTS