Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01875

Parcel: 12111162C


Addresses:

1636 N SWAN RD #103


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM01875

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/ test ok on underground soil and site wtr.
05/24/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/ 1) NO INTERMINGLING OF ABS AND PVC OR USE OF TRANSITION GLUE ON BLD INTERIOR DRAINAGE. CORRECT AND RETEST. 2) PROVIDE MID-SPAN SUPPORT OF VENT RISER, STUD OR VENT WILL NEED TO BE ACCESSABLE. 3) H20 PIPING WTR TEST OK. OK TO PARTIALLY COVER WASTE OUTSIDE BLD TO PROPERLY BED WTR PIPING.