Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/21/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BLOCK BETWEEN COMB 2) REMOVE ROOF PAPER FROM WATER HEATER FLUE 3) FINISH FIRE BLOCKING CHASE INSIDE FRONT DOOR 4) BANG PLATE KITCHEN ABS AT TOP PLATE 5) PROTECT STOVE WIRE FROM ROOF TRUSS GUSSETT IN KITCHEN 7) FIREBLOCK DRYER DUCT 8) H2.5 TRUSS IN SOUTH EAST BED CLOSET 9) SHIM HEADERS 10) FINISH X BRACE LIVING ROOM GABLE 11) SHIM TRUSS 3RD POINT AND STRAP SAME TOP PLATES 12) CORRECT TC CLIP NAILING 13) CLIP WEST END OF DOUBLE TRUSS IN MASTER |
|
| 07/19/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) MESH NOT FAR ENOUGH ALONG TO DO INTERMEDIATES |