Permit: T04CM01869

Parcel: 108163230

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/22/2004 FRAMING Approved IVRS - Inspection :*
07/21/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BLOCK BETWEEN COMB 2) REMOVE ROOF PAPER FROM WATER HEATER FLUE 3) FINISH FIRE BLOCKING CHASE INSIDE FRONT DOOR 4) BANG PLATE KITCHEN ABS AT TOP PLATE 5) PROTECT STOVE WIRE FROM ROOF TRUSS GUSSETT IN KITCHEN 7) FIREBLOCK DRYER DUCT 8) H2.5 TRUSS IN SOUTH EAST BED CLOSET 9) SHIM HEADERS 10) FINISH X BRACE LIVING ROOM GABLE 11) SHIM TRUSS 3RD POINT AND STRAP SAME TOP PLATES 12) CORRECT TC CLIP NAILING 13) CLIP WEST END OF DOUBLE TRUSS IN MASTER
07/19/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) MESH NOT FAR ENOUGH ALONG TO DO INTERMEDIATES