Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01868
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2004 | FRAMING | Approved | IVRS - Inspection :*/ 1) RE-INSPECT | |
06/25/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) BLOWN FIRE BLOCKS AT STAIR LANDING TO POWDER ROOM SIDE 2) OK TO INSULATE | |
06/24/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CLIP INTERIOR BEARING POINTS AT PANTRY 2) FIRE BLOCK LANDING AND 2ND FLOOR BEDROOMS 3) WATER LINES OK 4) VENT AT KITCHEN BELOW FLOOR RIM 5) EXHAUST FAN IN LAUNDRY DUCT SPLIT IN HALF |